GW Instek LCR-817
Precise LCR bridge RLC-817 (12Hz ~ 10kHz) RS-232
Search
Manufacturers
Precise LCR bridge RLC-817 (12Hz ~ 10kHz) RS-232
Features
※ Test Frequency:
12Hz~200kHz (LCR-821)
12Hz~100kHz (LCR-819/829)
12Hz~10kHz (LCR-817/827)
100Hz~2kHz (LCR-816/826)
※ 0.05%~0.1% Basic Accuracy
※ 100 Sets Memory for Save/Recall of Settings
※ R/Q, C/D, C/R, L/Q, Z/θ, L/R Test Modes
※ Absolute Value,ΔValue, and Δ% Measurement Display
※ 240 x 128 dot Matrix LCD Display
※ Displays Condition and Test Result Simultaneously
※ Standard Interface: RS-232C (LCR-821)/ Handler (LCR-829/827/826)
※ Optional Interface: RS-232C (LCR-819/817/816)
The LCR-800 Series are high-end digital LCR meters for component/material measurements, applicable to various R&D activities and assembly lines. The large 240 x 128 dot matrix LCD display provides ample room for two measurement items and setup parameters, allowing you to grasp measurement results quickly. All test modes are able to measure supplementary factors, such as, R/Q, C/D, C/R, and L/Q. The LCR-821 also contains precise resistance measurements as a combination of absolute value and phase angle. 100 sets of measurement setup memory allow sharing a single unit among multiple testing conditions or sites. For a better viewing experience in a standard PC monitor, proprietary Windows based software is accessible via the RS-232C terminal. The handler interface is also a standard feature for LCR-826/827/829.
TEST FREQUENCY | ||
12Hz ~ 200kHz (504 steps) for LCR-821 12Hz ~ 100kHz(503 steps) for LCR-819/829 12Hz ~ 10kHz(489 steps) for LCR-817/827 100Hz ~2kHz (245 steps) for LCR-816/826 | ||
BASIC ACCURACY (*) | ||
0.05% for basic accuracy for LCR-821/819/817 0.1% for basic accuracy for LCR-829/827/826/816 | ||
TEST SPEED | ||
68ms for LCR-821/819/817/816, 34ms for LCR-829/827/826 | ||
TEST SIGNAL LEVELS | ||
5mV ~ 1.275Vrms ( 5mV/step ) for LCR-821/819/829/817/827 0.1V ~ 1.275Vrms ( 5mV/step )for LCR-816/826 | ||
DC BIAS | ||
Internal | 2V | |
External | 0 ~ 35V for LCR-821; 0 ~ 30V for LCR-819/829/817/827/816/826 | |
DISPLAY RANGE (**) | ||
Resistance | R 0.00001Ω ~ 99999kΩ | |
Capacitance | C 0.00001pF ~ 99999uF | |
Inductance | L 0.00001mH ~ 99999H | |
Quality Factor | Q 0.0001 ~ 9999 | |
Dissipation Factor | D 0.0001 ~ 9999 | |
Impedance | |Z| 0.00001Ω ~ 99999kΩ for LCR-821 | |
Phase Angle (Degree) | θ -180.00° ~ 180.00° for LCR-821 | |
TEST MODE | ||
R/Q, C/D, C/R, L/Q, Z/θ, L/R for LCR-821 only | ||
EQUIVALENT CIRCUIT | ||
Parallel or series selectable | ||
MEMORY | ||
100 memory blocks total | ||
AVERAGE | ||
1 to 255 times | ||
TEST SPEED MODE | ||
SLOW, MEDIUM and FAST | ||
DISPLAY MODE | ||
Value, △, △% | ||
DISPLAY | ||
240 x 128 dot matrix C.C.F.L back light LCD | ||
INTERFACE | ||
Standard : RS-232C for LCR-821 Standard : Handler Interface for LCR-829/827/826 Optional : RS-232C Interface for LCR-819/817/816 (Including LCR-Viewer Software for RS-232C interface) | ||
POWER SOURCE | ||
Line Voltage Range | 100V - 240V, 47-63Hz/400Hz | |
DIMENSIONS & WEIGHT | ||
330(W) x 149(H) x 437(D)mm Approx. 5.5kg |
(*):Basic accuracy varies with the speed, frequency, AC signal level and impedance of the device under test.
(**):Display range refers to the range of measurement values that can be displayed on the screen. Please see the LCR-800 user manual for the effective measurement ranges.