Accuracy and versatility makes the HF LCR Meters the ideal choice for many different tasks and applications in manufacturing and test. The wide range of frequency specifications means that a model can be selected that best meets application requirements and within budget.

  • Precise high frequency impedance measurements
  • Characterize components from 20Hz to 120 MHz
  • Wide range of models with maximum frequencies from 5MHz (6505P ) to 120MHz (65120P )
  • 0.05% basic measurement accuracy
  • Comprehensive measurement functions
  • Easy to use with large TFT touch screen
  • Clear graphic displays aids measurements
  • Resonance Search
  • Intuitive user interface
  • Fully programmable over GPIB and LAN
  • Keyboard and mouse optional control
  • Competitively priced
6500P1 6500P2

Measurement parameters:     
      Capacitance (C)
      Inductance (L)
      Resistance (R)
      Reactance (X)
      Conductance (G)
      Susceptance (B)
      Dissipation Factor (D)
      Quality Factor (Q)
      Impedance (Z)
      Admittance (Y)
      Phase Angle (Ø)
High measurement accuracyCapacitance, inductance and impedance basic accuracy is an excellent ±0.05%. Dissipation factor accuracy is ±0.0005 and the quality factor accuracy is ±0.05%.Variable drive and bias levelsAC drive levels up to 1V or 20mA can be selected to evaluate components in realistic operating environments.The /D1 DC bias option provides 0 to +40V dc bias voltage and 0 to +100mA dc bias current while the /D2 option provides -40V to +40V dc bias voltage.External controlThe GPIB interface is used to control the instrument and read back measured values for applications such as quality control or for archiving purposes.An Ethernet interface similarly allows the instrument to be controlled and to send out data - allowing it to be integrated into many test environments.Wide range of interfacesAn external monitor or projector may be connected to the instrument's VGA output. The ability to provide a large screen display is invaluable in production environments or for teaching and training.Instrument control from both a keyboard and mouse is available. Any keyboard or mouse, with either PS/2 or USB interfaces, can be simply connected to provide an alternative method of instrument control and operation.Data storage and retrievalAll measurement and setup data can be stored using the Ethernet interface or a USB flash memory (supplied as standard).Setup dataUp to 20 instrument setups may be stored locally.Bin handlingThe /B1 option (non-isolated 5V) or /B2 option (isolated 24V) signals are available through a 25-way D-type connector. 10 bins can be set using absolute or percentage limits.Printer outputsHard copy printouts can be obtained in a number of ways including direct to an HP-PCL compatible graphics printer or Epson compatible text/ticket printer. A networked  HP-PCL compatible printer may also be used via Ethernet connection.Component connectionsFour front panel BNC connectors permit three or four terminal connections with the screens at ground potential.The 1J1011 component fixture, supplied as standard, ensures optimum performance when measuring a wide range of components of leaded components and devices.1J1012 (2 Terminal) and 1J1014 (4 Terminal) fixtures allow connection to surface mount devices.Protection against charged capacitorsHigh precision measuring instruments can be damaged by charged capacitors which can cause costly repairs and unacceptable downtime. All the models in the range incorporate protection against charged capacitors.Comprehensive and precise component tests at higher frequenciesThe 6500P series capabilities are best summarised by “Comprehensive and precise component tests at higher frequencies”. The instruments are the perfect solution for those who have demanding component measurement needs.

Technical Specifications 
Specification applies to all LCR meters in the range unless a model number or option is specified. 
Measurement parameters
Any of the following parameters can be measured and displayed:

AC Functions
      Capacitance (C)
      Inductance (L)
      Resistance (R)
      Reactance (X)
      Conductance (G)
      Susceptance (B)
      Dissipation Factor (D)
      Quality Factor (Q)
      Impedance (Z)
      Admittance (Y)
      Phase Angle (Ø)
Display format
Series or parallel equivalent circuit - all parameters

Test conditions 
Frequency range:
6505P    20Hz to 5MHz
6510P   20Hz to 10MHz
6515P    20Hz to 15MHz
6520P    20Hz to 20MHz
6530P    20Hz to 30MHz
6550P    20Hz to 50MHz
65120P 20Hz to 120MHz
Frequency step size: < 1mHz
Accuracy of set frequency ±0.005%
AC Drive level
10 mV to 1V rms*
200 µA to 20 mA rms*
*Varies with frequency
Signal source impedance: 50 Ω nominal
DC Bias (option)
/D1 0 to +100mA dc bias current and 0 to +40V dc bias voltage
/D2 -40V to +40V dc bias voltage
Binning (option)
10 bins with absolute and percentage limits
25 way D-type interface connector 
/B1 (Non-Isolated) 
Common 0V. Bin outputs 0 to 5V (nominal) with >10mA current sink capability
/B2 (Isolated)
Common 24V input. Outputs 0 to 24V with >10mA current source capability.
Setup data
Up to 20 instrument setups may be stored locally.

Measurement connections
Four front panel BNC connectors permit two, three or four terminal connections with the screens at ground potential.
1J1011 Component Fixture (supplied as standard) allows connection to leaded components and devices.
1J1012 (2 Terminal) and 1J1014 (4 Terminal) fixtures allow connection to surface mount devices.

Measurement accuracy
Dissipation factor
±0.0005 (1+D2)**
Quality factor
±0.05 %( Q+1/Q)**
Capacitance / Inductance / Impedance
±0.05%**
*Varies with frequency, drive level and measured impedance

General
Power supply
Input voltage 90 V AC to 264 V AC (Autoranging)
Mains frequency
47 to 63 Hz
Display
8.4″ VGA (640 x 480) colour TFT with touch panel
Local printer
HP-PCL compatible graphics printing
Centronics / parallel printer port, Epson compatible text / ticket printing
Network printer
HP-PCL compatible graphics printing
Remote trigger
Rear panel BNC with internal pull-up, operates on logic low or contact closure
GPIB interface
External instrument control. 24 pin IEEE 488 connector
USB interface
Two Universal Serial Bus Interfaces
USB 1.1 compliant
VGA interface
15-way D-type connector to drive an external monitor in addition to the internal screen
Network interface
10/100-BASETX Ethernet controller.
RJ45 connector
Keyboard interface
Standard USB or PS/2 keyboard port. Instrument front panel remains active with keyboard plugged in.
Mouse interface
Standard USB or PS/2 mouse port.
Touch screen remains enabled when the mouse is connected.
Bin handler (option)
/B1 Isolated (24 V) and /B2 non-isolated (5 V).
25-way D-type connector

Environmental conditions
This equipment is intended for indoor use only in a non-explosive and non-corrosive atmosphere
Temperature Range
Storage -20°C to 60°C
Operating 0°C to 40°C
Full Accuracy 18°C to 28°C
Relative humidity
Up to 80% non-condensing
Altitude
Up to 2000m
Installation category
II in accordance with IEC664
Pollution degree
2 - mainly non-conductive
Safety
Complies with the requirements of EN61010-1
EMC
Complies with EN61326 for emissions and immunity
Mechanical
Height 190 mm (7.5″)
Width 440 mm (17.37″)
Depth 525 mm (20.5″)
Weight 13.8 kg (32 lb)
 
  • Frequency max. 5 MHz