GW Instek GDS-1072A-U
Digital oscilloscope GDS-1072-U 2x70MHz 1GSa/s, memory 2M - Recorder
Search
Manufacturers
Digital oscilloscope GDS-1072-U 2x70MHz 1GSa/s, memory 2M - Recorder
GDS-1072A-U | GDS-1102A-U | GDS-1152A-U | |
VERTICAL | |||
Channels | 2 | 2 | 2 |
Bandwidth | DC~70MHz(-3dB) | DC~100MHz(-3dB) | DC~150MHz(-3dB) |
Rise Time | <5ns Approx. | <3.5ns Approx. | <2.3ns Approx. |
Sensitivity | 2mV/div ~ 10V/div (1-2-5 increments) | ||
Accuracy | ±(3% x |Readout| + 0.1 div + 1mV) | ||
Input Coupling | AC, DC & Ground | ||
Input Impedance | 1MΩ±2%, ~15pF | ||
Polarity | Normal & Invert | ||
Maximum Input | 300V (DC+AC peak), CATII | ||
Waveform Signal Process | + , - , x, FFT, FFTrms ,Zoom FFT | ||
Offset Range | 2mV/div ~ 50mV/div: ±0.4V 100mV/div ~ 500mV/div: ±4V 1V/div ~ 5V/div: ±40V 10V/div: ±300V | ||
Bandwidth Limit | 20MHz (-3dB) | ||
TRIGGER | |||
Sources | CH1 , CH2 , Line , EXT | ||
Modes | Auto, Normal, Single, TV, Edge, Pulse Width | ||
Coupling | AC , DC , LF rej. , HF rej. , Noise rej. | ||
Sensitivity | DC ~ 25MHz: Approx. 0.5div or 5mV; 25MHz ~ 70/100/150MHz: Approx. 1.5div or 15mV | ||
EXT TRIGGER | |||
Range | ±15V | ||
Sensitivity | DC ~ 25MHz : ~ 50mV ; 25M ~ 70/100/150MHz : ~15mV | ||
Input Impedance | 1MΩ±2% , ~ 15pF | ||
Maximum Input | 300V (DC AC peak) , CATII | ||
HORIZONTAL | |||
Range | 1ns/div ~ 50s/div (1-2.5-5 increments); ROLL : 50ms/div ~ 50s/div | ||
Modes | Main, Window, Window Zoom, Roll, X-Y | ||
Accuracy | ±0.01% | ||
Pre-Trigger | 10 div maximum | ||
Post-Trigger | 1000 div | ||
X-Y MODE | |||
X-Axis Input | Channel 1 | ||
Y-Axis Input | Channel 2 | ||
Phase Shift | ±3°at 100kHz | ||
SIGNAL ACQUISITION | |||
Real-Time Sample Rate | 1GSa/s maximum | ||
Equivalent Sample Rate | 25GSa/s maximum | ||
Vertical Resolution | 8 Bits | ||
2 Mega Points maximum | |||
Acquisition Mode | Normal, Peak Detect, Average | ||
Peak Detection | 10ns (500ns/div ~ 10s/div) | ||
Average | 2 , 4 , 8 , 16 , 32 , 64 , 128 , 256 | ||
CURSORS AND MEASUREMENT | |||
Voltage Measurement | Vpp ,Vamp ,Vavg ,Vrms ,Vhi ,Vlo ,Vmax ,Vmin ,Rise Preshoot/Overshoot ,Fall Preshoot/Overshoot | ||
Time Measurement | Freq ,Period ,Rise Time ,Fall Time ,Positive Width ,Negative Width ,Duty Cycle | ||
Cursors Measurement | Voltage difference between cursors (V) Time difference between cursors (T) | ||
Auto Counter | Resolution : 6 digits Accuracy: 2% Signal Source: All available trigger source except the Video trigger mode | ||
ADJUSTABLE PROBE COMPENSATION SIGNAL | |||
Frequency Range | 1kHz ~ 100kHz, 1kHz/STEP | ||
Duty Cycle Range | 5% ~ 95%, 5%/STEP | ||
CONTROL PANEL FUNCTION | |||
Autoset | Adjust Vertical VOLT/DIV, Horizontal TIME/DIV, and Trigger level automatically | ||
Save Setup | Up to 15 sets of measurement conditions | ||
Save Waveform | 15 sets of waveform | ||
DISPLAY | |||
TFT LCD Type | 5.7 inch | ||
Display Resolution | 234(Vertically) x 320(Horizontally) Dots | ||
Display Graticule | 8 x 10 divisions | ||
Display Brightness | Adjustable | ||
INTERFACE | |||
USB Device | USB1.1 & 2.0 full speed compatible | ||
USB Host | Image (BMP), waveform data (CSV), and setup (SET) | ||
POWER SOURCE | |||
Line Voltage Range | AC 100V ~ 240V , 48Hz ~ 63Hz , Auto selection | ||
MISCELLANEOUS | |||
Multi-Language Menu | Available | ||
Onscreen Help | Available | ||
DIMENSIONS & WEIGHT | |||
310(W) x 142 (H) x 140(D)mm, Approx. 2.5kg |