Maximize
GW Instek GCM-403
Digital Clamp Meter GCM-403 ACA, ACV, DCV, Ohm, Diode, Buzzer
Search
Manufacturers
Digital Clamp Meter GCM-403 ACA, ACV, DCV, Ohm, Diode, Buzzer
GCM-403 | GCM-407 | |
ACV | ||
Range | 4V, 40V, 400V, 600V | 6V, 60V, 600V, 750V |
Resolution | 0.001V, 0.01V, 0.1V, 1V | 0.001V, 0.01V, 0.1V, 1V |
Accuracy | ±(1.0 + 5) ~ ±(1.2 + 5) | ±(1.2 + 5) ~ ±(1.5 + 5) |
Input Impedance | ≧10MΩ // 100pF at least | ≧10MΩ |
Frequency Response | 40~400Hz | 40~400Hz |
ACA | ||
Range | 40A, 600A | 6A, 60A, 600A |
Resolution | 0.01A, 0.1A | 0.001A, 0.01A, 0.1A |
Accuracy | ±(2.5 + 5) ~ ±(2.5 + 8) | ±(2.5 + 5) ~ ±(2.5 + 30) |
Frequency Response | 50~60Hz | 50~60Hz |
DCV | ||
Range | 400mV, 4V, 40V, 400V, 600V | 600mV, 6V, 60V, 600V, 1000V |
Resolution | 0.1mV, 0.001V, 0.01V, 0.1V, 1V | 0.1mV, 0.001V, 0.01V, 0.1V, 1V |
Accuracy | ±(0.8 + 1) ~ ±(1.0 + 3) | ±(0.8 + 1) ~ ±(1.0 + 8) |
Input Impedance | ≧10MΩ | ≧10MΩ |
DCA | ||
Range | 40A, 600A | - |
Resolution | 0.01A, 0.1A | - |
Accuracy | ±(2.0 + 5) | - |
OHM | ||
Range | 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ | 600Ω, 6kΩ, 60kΩ, 600kΩ, 6MΩ, 60MΩ |
Resolution | 0.1Ω, 0.001kΩ, 0.01kΩ, 0.1kΩ, 0.001MΩ, 0.01MΩ | 0.1Ω, 0.001kΩ, 0.01kΩ, 0.1kΩ, 0.001MΩ, 0.01MΩ |
Accuracy | ±(1.0 + 2) ~ ±(1.5 + 2) | ±(1.0 + 2) ~ ±(1.5 + 5) |
DIODE | ||
Range | 4V | 6V |
Resolution | 0.001V | 0.001V |
Open-circuit Voltage | Approx. 1.48V | Approx. 3.3V |
CONTINUITY | ||
Range | 400Ω | 600Ω |
Resolution | 0.1Ω | 0.1Ω |
Accuracy | The buzzer turns on for resistance lower than 10Ω | The buzzer turns on for resistance lower than 30Ω |
Open-circuit Voltage | Approx. 0.45V | Approx. 1.2V |
CAPACITANCE | ||
Range | 40nF, 400nF, 4uF, 40uF, 100uF | 99nF, 999nF, 9uF, 99uF, 999uF, 9mF, 59mF |
Resolution | 0.01nF, 0.1nF, 0.001uF, 0.01uF, 0.1uF | 0.01nF, 0.1nF, 0.001uF, 0.01uF, 0.1uF, 0.001mF, 0.01mF |
Accuracy | ±(4.0 + 3) ~ ±(5.0 + 10) | ±(4.0 + 5) ~ ±10 |
FREQUENCY | ||
Range | 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz, 10MHz | - |
Resolution | 0.001Hz, 0.01Hz, 0.1Hz, 1Hz, 10Hz, 100Hz, 1kHz | - |
Accuracy | ±(4.0 + 3) ~ ±(5.0 + 10) | - |
NCV (Non-Contact Voltage) | ||
Distance | - | < 10mm |
Sensing | - | AC Voltage only |
TEMPERATURE (˚C only) | ||
Range | -40˚C ~ 1000˚C | - |
Accuracy | ±(2.5 + 3) ~ ±(8.0 + 5) | - |
OTHER FUNCTION | ||
Data Hold, REL | Data Hold, MAX/MIN, REL, Backlight, Flashlight | |
LCD DISPLAY | ||
Liquid crystal display: Displays 4000 counts maximum. | Liquid crystal display: Displays 6000 counts maximum. | |
CLAMP OPENING DIAMETER | ||
28mm Maximum | 30mm Maximum | |
POWER SOURCE | ||
9V battery (16F22) | 3 AAA 1.5V zinc manganese batteries | |
DIMENSIONS & WEIGHT | ||
210 (L) x 76 (W) x30 (H) mm; Approx. 260g | 228 (L) x 77 (W) x41 (H) mm; Approx. 265g (inclusive of the battery) |