Search

Categories

  New 
  Used 

Manufacturers

VC187

AC voltage, DC voltage, AC current ,DC current, OHM, Frequency, Period, Pulse width,Capacitance, Beep, Diode, dBm, TC, RTD, AC+ DC, AC + Hz, Max, Min, MAX / MIN / AVG, REL_%

More details

Availability: This product is no longer in stock


Notify me when available

365,31 €

297,00 € tax excl.

Description:
Measurements
AC voltage, DC voltage, AC current ,DC current, OHM, Frequency, Period, Pulse width,Capacitance, Beep, Diode, dBm, Thermocouple (TC), Thermal resistance (RTD), AC+ DC, AC + Hz measurement, Maximum, Minimum, Average measurement (MAX / MIN / AVG), The relative value measurement (REL_%)
          Measurements show that 55,000 words, the basic accuracy 0.02% (VICTOR 189)  /  0.05% (VICTOR 187)
          Three measurement rate: FAST, SLOW, SMOOTH, the fastest refresh rate of simulation bar: 14 / sec
          Manual range or automatic range selection
          Measuring data show that hold functional (DIS_HOLD) and automatically hold functions(AUTO_HOLD)
          Peak measurements, 500us peak sampling capture, capable of capturing crest Pulse
          AC voltage and AC current are true rms measurement, AC voltage bandwidth 20Hz~30KHz(VICTOR 187),20Hz-100KHz(VICTOR 189), AC current bandwidth 20Hz-30KHz
          Option 1 ~ 2400 Ω reference impedance measurement of decibels
          Low pass filter function normally by the RP-raising and the frequency of the electrical waveform measurement results
          Can be configured clamp to measure the large current
          The eight kinds of thermocouple measurement, the two kinds of heat resistance measurement, high-precision cold-automatic compensation, ℃ or ℉ temperature display
          Large-screen display and more data can be displayed at the same time that is measurements and other information related to the measurement
          Built-in real-time clock, for the record and provide accurate measurement of time
          Easy to operate multi-parameter data record: manual records and records of the incident, and easy to query the data records
          Adopted panel calibration technology, can be done without opening the case calibration
          Use alkaline batteries, Ni-Hi battery-powered, the battery and fuse can be easily replaced.
          Backlight is automatically closed and automatic power off function
          Large-screen LCD display, with white LED backlighting
          The meter can communicate with computer by isolation interface USB
          Through the friendly interface, users can easily access the data of instrument in a number of parameters, and may be the data storage, processing, management, access to the data tables and other graphics or display
l          Simple man-machine operating, delicate, strongly and suitable for field use
Specifications for products

\"\\"\\\\"\\\\"\\"\"
MeasurementsRangeMeasuring rangeResolution
DCV5.0000V0.0001VInput impedance:
10MΩ
50.000V0.001V
500.00V0.01V
1000.0V0.1V
DCmV50.000mV0.001mVInput impedance:
approx. 100MΩ
500.00mV0.01mV
2200.0mV0.1mV
ACV5.0000V0.0001VInput impedance:
10MΩ / 50pF
CF<3
187:
20Hz~30kHz
(10~110% Range)

 
50.000V0.001V
500.00V0.01V
760.0V0.1V
ACmV50.000mV0.001mVInput impedance:
1MΩ / 50pF
500.00mV0.01mV
OHM500.00Ω0.01ΩOpen circuit voltage
<2.5V
5.0000KΩ0.0001KΩ
50.000KΩ0.001KΩ
500.00KΩ0.01KΩ
5.0000MΩ0.0001 MΩ
50.000MΩ0.001 MΩ
500.0MΩ0.1 MΩ
DCA5.0000A0.0001 AVoltage Drop <0.04 V/A
20.000A0.001 A
DCmA50.000mA0.001mAVoltage Drop
<1.8 mV/mA
500.00mA0.01 mA
DCuA500.00uA0.01 uAVoltage Drop
103uV/uA
5000.0uA0.1 uA
5.0000A0.0001 A
ACmA50.000mA0.001mA
500.00mA0.01 mA
ACuA500.00uA0.01uA
50000uA0.1uA
FREQ9.9999Hz0.0001Hz 
99.999Hz0.001Hz
999.99Hz0.01Hz
9.9999KHz0.0001KHz
99.999KHz0.001KHz
999.99KHz
0.01KHz
9.9999MHz0.0001MHz
99.999MHz0.001MHz
DUTY0.1%~99.9%0.1%0.5Hz~1KHz,
Square Wave
 
PULSE
199.99ms0.01ms
1999.9ms0.1ms
DIODE2.2000V0.0001VOpen circuit voltage:<3.5V
Short circuit:0.8mA
CHCNT500.0Ω0.1ΩOpen circuit voltage:<3.5V
Short circuit:<0.8mA
Short alarm:approx. <20Ω
Open alarm:approx. >120Ω
CAP9.999nF0.001nF 
99.99nF0.01nF
999.9nF0.1nF
9.999μF0.001uF
99.99μF0.01uF
999.9μF0.1uF
9.999mF0.001mF
99.99mF0.01mF
TCR-40°C~1760°C1°CITS-90
S-40°C~1760°C
K-270.0~1370.00.1°C
E-270.0~720.00.1°C
J-210.0~850.00.1°C
T-270.0~400.00.1°C
N-270.0~1300.00.1°C
B400~18001°C
RTDPt100-200.0~850.00.1°CPt100-385
Pt1000-200.0~630.00.1°C
 
Other Features:
          DC Voltage measurement
CMRR:50Hz / 60Hz   ≥ 120dB
SMRR:50Hz / 60Hz(Rs=1kΩ) ≥ 80dB
          AC Voltage measurement
CMRR:50Hz / 60Hz(Rs=1kΩ) ≥ 80 dB
A residual reading  with input shorted, will not affect stated accuracy above 5 % of range.
          OHM measurement
For relative humidity greater than 70 %, resistance accuracy is 0.5 % over 1 MΩand 2.5 % over 10 MΩ.
          Internal temperature compensation sensor RJC:
temperature range: -10 ~ 50℃, compensation error ≤ ± 0.5 ℃, compensation time for 10 seconds each time   
          Maximum voltage between any Terminal and Earth Ground :
1000V DC / AC rms 
Fuse protection for mA input: 500 mA / 250V FAST fuse 
fuse protection for 20A input: 20 A / 250V FAST fuse 
Can be as high as 20 A continuous measurement of the current, if the signal detected in 10 A ~ 20 A of maintaining maximum of 30 seconds, then specified the need to increase the accuracy of 0.5%
          Real-Time Clock 
 ≤ ± 1min / 1month 
Temp. Influence 50 ppm per C
          Measured rate


Functional rangeMeasuring rate
FASTSLOWSMOOTH
DC voltage and current1471
AC voltage and current14/1.8
Resistors, diodes, on-off7/1.8

 
General Specifications:
          Operating Temperature and Humidity
0 to 50oC,(no condensation ≤10oC)  ≤ 85%RH
          Storage Temperature and Relative Humidity
     -20oC to 60oC,≤90%RH
          Altitude
2000m max. above sea level
          Rated transient over-voltage
6KV(1.2*50us)CATⅠ, CAI Ⅱ, CAT  Ⅲ  peak  measurement
          Vibration and Shock
Random 2g, 5 to 500Hz
1 meter drop test
        Period of calibration and warm-up time
Accuracy is specified for a period of one year after calibration or other
Warm-up time is 10 minutes or other
        Display and LED
* LCD:36.3×68.0mm
* white LED,able to set time 0~9999S
        Supply
* 4 x 1.5V Alkaline batteries supply
                    * 4 x 1.2V Ni-Hi batteries supply
                    * Auto Power-off:able to set time 0~9999minutes
        Safety Standards
IEC 61010-1, 2000
Overvoltage category III (Max. input voltage:AC/DC600V)
Overvoltage category II (Max. input voltage:AC/DC1000V)
Pollution degree 2
        Weight and Size
205 × 95 × 42(mm) ,approximate 500g