 Maximize
 Maximize GW Instek GDS-122
Handhel Digital storage oscilloscope & Multimeter
Search
Manufacturers
Viewed products
 Maximize
 Maximize Handhel Digital storage oscilloscope & Multimeter
Features
* 20MHz Bandwidth 
* 100MS/s Real-Time Sampling Rate 
* True RMS Multimeter: Volt, AMp, Ohm, Continuity, Diode 
* Dual Independent Floating Isolated Channels
* Trigger Mode: Free Run, Single Shot, Edge, Video 
* USB Interface 
* 6 Hour Capacity Li-ion Rechargeable Battery 
* 3.8" Color LCD, Resolution: 320 x 240 
* Light Weight: 690g
| 
 | |
| Channels | 2 | 
| Analog Bandwidth | 20MHz | 
| Single Bandwidth | Full bandwidth | 
| Rise Time | 17.5ns | 
| Sensitivity | 5mV/div ~ 5V/div at the BNC input | 
| DC Gain Accuracy | ±5% | 
| DC Measurement Accuracy | ±(5% reading + 0.05div): average sampling | 
| Analog Digital Converter Resolution | 8 bits, synchronously sampling on both channels | 
| Displacement Range | ±50V (500mV ~ 5V), ±1V (5mV ~ 200mV) | 
| Low Frequency Response AD Coupling, -3dB | ±5Hz at the BNC input | 
| 
 | |
| Sources | CH1, CH2 | 
| Trigger Sensitivity | 2div, peak-to-peak value | 
| Trigger Sensitivity Edge Trigger | DC coupling: 1div (full bandwidth) AC coupling: same as the DC coupling (≧50Hz) | 
| Trigger Level Range | ±6div from the screen center | 
| Trigger Level Accuracy | ±0.3div typical | 
| Trigger Displacement | 655div (pre-trigger), 4div (post-trigger) | 
| 50% Level Setting | Input signal ≧50Hz (typical) | 
| Video Trigger | NTSC, PAL, SECAM (any line or frequency) | 
| 
 | |
| Sampling Rate | 10S/s ~ 100MS/s | 
| Waveform Interpolation | sinx/x | 
| Record Length | 6k points on each channel | 
| Scan Speed | 5ns/div ~ 5s/div, 1-2.5-5 step | 
| Sampling Rate and Relay Time Accuracy | ±100ppm (≧1ms) | 
| Time Interval Accuracy (Full Bandwidth) | Single: ±(1 sampling interval time + 100ppm x reading + 0.6ns) Average >16: ±(1 sampling interval time + 100ppm x reading + 0.4ns) | 
| 
 | |
| Input Coupling | DC, AC | 
| Input Impedance | 1MΩ ±2%, connected in parallel with 20pF±3pF | 
| Probe Attenuation Coefficient | 1X, 10X, 100X, 1000X | 
| Maximum Input Voltage | 400V (peak) | 
| Channel Delay Time | 150ps (typical) | 
| 
 | |
| Sampling Mode | Normal, Peak Detect, Average | 
| Sampling Rate | 100MSa/s | 
| 
 | |
| Cursor Measurement | Voltage difference and Time difference between cursors | 
| Auto Measurement | Peak-to-peak, Average, Root mean square, Frequency, Cycle | 
| 
 | |
| Input Impedance | 10MΩ | 
| Voltage | VDC: 400mV, 4V, 400V ±(1% + 1digit) VDC: 4V, 40V, 400V ±(1% + 3digits) | 
| Maximum Input Voltage | DC 400V, AC 400V (virtual value) | 
| Frequency | 40Hz ~ 400Hz | 
| DC Current | 40mA, 400mA ±(1.5% + 1digit), 20A ±(3% + 3digits) | 
| AC Current | 40mA ±(1.5% + 3digits), 400mA ±(2% + 1digit), 20A ±(5% + 3digits) | 
| Impedance | 400Ω ±(1% + 3digits), 4kΩ, 40kΩ, 400kΩ, 4MΩ ±(1% + 1digit), 40MΩ ±(1.5% + 3digits) | 
| Capacitance | 51.2nF ~ 100uF ±(3% + 3digits) | 
| Diode | 0V ~ 1.5V on/off measurement < 50Ω (±30Ω) beep | 
| 
 | |
| Display Type | 3.8" color liquid crystal display | 
| Display Resolution | 320 (horizontal) x 240 (vertical) pixels | 
| Display Color | 4096 colors | 
| Power Supply | 100 ~ 240VAC, 50Hz, CATII | 
| Power Consumption | <6W | 
| Operating Temperature | Battery Operation: 0 ~ 50℃ (32 ~ 122F) Power adaptor operation: 0 ~ 40℃ (32 ~ 104F) | 
| Dimensions & Weight | 180 x 115 x 40 mm; Approx 0.69kg |