 Maximize
 Maximize GW Instek GCM-407
Digital Clamp Meter GCM-407 ACA, ACV, DCV, Ohm, Diode, Buzzer, NCV, REL
Search
Manufacturers
 Maximize
 Maximize Digital Clamp Meter GCM-407 ACA, ACV, DCV, Ohm, Diode, Buzzer, NCV, REL
| GCM-403 | GCM-407 | |
| ACV | ||
| Range | 4V, 40V, 400V, 600V | 6V, 60V, 600V, 750V | 
| Resolution | 0.001V, 0.01V, 0.1V, 1V | 0.001V, 0.01V, 0.1V, 1V | 
| Accuracy | ±(1.0 + 5) ~ ±(1.2 + 5) | ±(1.2 + 5) ~ ±(1.5 + 5) | 
| Input Impedance | ≧10MΩ // 100pF at least | ≧10MΩ | 
| Frequency Response | 40~400Hz | 40~400Hz | 
| ACA | ||
| Range | 40A, 600A | 6A, 60A, 600A | 
| Resolution | 0.01A, 0.1A | 0.001A, 0.01A, 0.1A | 
| Accuracy | ±(2.5 + 5) ~ ±(2.5 + 8) | ±(2.5 + 5) ~ ±(2.5 + 30) | 
| Frequency Response | 50~60Hz | 50~60Hz | 
| DCV | ||
| Range | 400mV, 4V, 40V, 400V, 600V | 600mV, 6V, 60V, 600V, 1000V | 
| Resolution | 0.1mV, 0.001V, 0.01V, 0.1V, 1V | 0.1mV, 0.001V, 0.01V, 0.1V, 1V | 
| Accuracy | ±(0.8 + 1) ~ ±(1.0 + 3) | ±(0.8 + 1) ~ ±(1.0 + 8) | 
| Input Impedance | ≧10MΩ | ≧10MΩ | 
| DCA | ||
| Range | 40A, 600A | - | 
| Resolution | 0.01A, 0.1A | - | 
| Accuracy | ±(2.0 + 5) | - | 
| OHM | ||
| Range | 400Ω, 4kΩ, 40kΩ, 400kΩ, 4MΩ, 40MΩ | 600Ω, 6kΩ, 60kΩ, 600kΩ, 6MΩ, 60MΩ | 
| Resolution | 0.1Ω, 0.001kΩ, 0.01kΩ, 0.1kΩ, 0.001MΩ, 0.01MΩ | 0.1Ω, 0.001kΩ, 0.01kΩ, 0.1kΩ, 0.001MΩ, 0.01MΩ | 
| Accuracy | ±(1.0 + 2) ~ ±(1.5 + 2) | ±(1.0 + 2) ~ ±(1.5 + 5) | 
| DIODE | ||
| Range | 4V | 6V | 
| Resolution | 0.001V | 0.001V | 
| Open-circuit Voltage | Approx. 1.48V | Approx. 3.3V | 
| CONTINUITY | ||
| Range | 400Ω | 600Ω | 
| Resolution | 0.1Ω | 0.1Ω | 
| Accuracy | The buzzer turns on for resistance lower than 10Ω | The buzzer turns on for resistance lower than 30Ω | 
| Open-circuit Voltage | Approx. 0.45V | Approx. 1.2V | 
| CAPACITANCE | ||
| Range | 40nF, 400nF, 4uF, 40uF, 100uF | 99nF, 999nF, 9uF, 99uF, 999uF, 9mF, 59mF | 
| Resolution | 0.01nF, 0.1nF, 0.001uF, 0.01uF, 0.1uF | 0.01nF, 0.1nF, 0.001uF, 0.01uF, 0.1uF, 0.001mF, 0.01mF | 
| Accuracy | ±(4.0 + 3) ~ ±(5.0 + 10) | ±(4.0 + 5) ~ ±10 | 
| FREQUENCY | ||
| Range | 10Hz, 100Hz, 1kHz, 10kHz, 100kHz, 1MHz, 10MHz | - | 
| Resolution | 0.001Hz, 0.01Hz, 0.1Hz, 1Hz, 10Hz, 100Hz, 1kHz | - | 
| Accuracy | ±(4.0 + 3) ~ ±(5.0 + 10) | - | 
| NCV (Non-Contact Voltage) | ||
| Distance | - | < 10mm | 
| Sensing | - | AC Voltage only | 
| TEMPERATURE (˚C only) | ||
| Range | -40˚C ~ 1000˚C | - | 
| Accuracy | ±(2.5 + 3) ~ ±(8.0 + 5) | - | 
| OTHER FUNCTION | ||
| Data Hold, REL | Data Hold, MAX/MIN, REL, Backlight, Flashlight | |
| LCD DISPLAY | ||
| Liquid crystal display: Displays 4000 counts maximum. | Liquid crystal display: Displays 6000 counts maximum. | |
| CLAMP OPENING DIAMETER | ||
| 28mm Maximum | 30mm Maximum | |
| POWER SOURCE | ||
| 9V battery (16F22) | 3 AAA 1.5V zinc manganese batteries | |
| DIMENSIONS & WEIGHT | ||
| 210 (L) x 76 (W) x30 (H) mm; Approx. 260g | 228 (L) x 77 (W) x41 (H) mm; Approx. 265g (inclusive of the battery) | |