| Model | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
| Rated Output Voltage | V | 30 | 80 | 160 | 250 | 800 | |
| Rated Output Current | A | 108 | 40.5 | 21.6 | 13.5 | 4.32 | |
| Rated Output Power | W | 1080 | 1080 | 1080 | 1080 | 1080 | |
| Power Ratio | -- | 3 | 3 | 3.2 | 3.125 | 3.2 | |
| Constant Voltage Mode | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
| Line Regulation (*1) | mV | 18 | 43 | 83 | 128 | 403 | |
| Load Regulation (*2) | mV | 20 | 45 | 85 | 130 | 405 | |
| Ripple and Noise (*3) | |||||||
| p-p (*4) | mV | 100 | 100 | 100 | 120 | 200 | |
| r.m.s (*5) | mV | 14 | 14 | 20 | 15 | 30 | |
| Temperature coefficient | ppm/°C | 100ppm/°C of ra ted output voltage, after a 30 minute warm-up. | |||||
| Remote sense compensation voltage | V/wire | 0.6 | 0.6 | 0.6 | 1 | 1 | |
| Rise Time (*6) | |||||||
| Rated Load | ms | 50 | 50 | 100 | 100 | 150 | |
| No Load | ms | 50 | 50 | 100 | 100 | 150 | |
| Fall Time (*7) | |||||||
| Rated Load | ms | 50 | 50 | 100 | 150 | 300 | |
| No Load | ms | 500 | 500 | 1000 | 1200 | 2000 | |
| Transient response time (*8) | ms | 1 | 1 | 2 | 2 | 2 | |
| Constant Current Mode | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
| Line regulation (*1) | mA | 113 | 45.5 | 26.6 | 18.5 | 9.32 | |
| Load regulation (*9) | mA | 113 | 45.5 | 26.6 | 18.5 | 9.32 | |
| Ripple and noise | |||||||
| r.m.s (*5 ) | mA | 216 | 81 | 45 | 30 | 15 | |
| Temperature coefficient | ppm/°C | 200ppm/°C of rated output current, after a 30 minute warm-up . | |||||
| Protection Function | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
| Over voltage protection (OVP) | |||||||
| Setting range | V | 3-33 | 8-88 | 16-176 | 20-275 | 20-880 | |
| Setting accuracy | ± (2% of rated output voltage) | ||||||
| Over current protection (OCP) | |||||||
| Setting range | A | 5-118.8 | 4.05-44.55 | 2.16-23.76 | 1.35-14.85 | 0.432-4.752 | |
| Setting accuracy | ± (2% of rated output current) | ||||||
| Over temperature protection (OTP) | |||||||
| Operation | Turn the output off. | ||||||
| Low AC input protection (AC-FAIL) | |||||||
| Operation | Turn the output off. | ||||||
| Power limit (POWER LIMIT) | |||||||
| Operation | Over power limit. | ||||||
| Value (fixed) | Approx. 105% of rated output power | ||||||
| Front Panel | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
| Display, 4 digits | |||||||
| Voltage accuracy 0.1% + | mV | 20 | 20 | 100 | 200 | 400 | |
| Current accuracy 0.1% + | mA | 100 | 50 | 30 | 20 | 6 | |
| Programming and Measurement (Interface) | PSW | 30-108 | 80-40.5 | 160-21.6 | 250-13.5 | 800-4.32 | |
| Voltage programming accuracy 0.1% + | mV | 10 | 10 | 100 | 200 | 400 | |
| Current programming accuracy 0.1% + | mA | 100 | 40 | 20 | 15 | 6 | |
| Voltage programming resolution | mV | 1 | 2 | 3 | 5 | 14 | |
| Current programming resolution | mA | 3 | 3 | 3 | 1 | 1 | |
| Voltage measurement accuracy 0.1% + | mV | 10 | 10 | 100 | 200 | 400 | |
| Current measurement accuracy 0.1% + | mA | 100 | 40 | 20 | 15 | 6 | |
| Voltage measurement resolution | mV | 1 | 2 | 3 | 5 | 14 | |
| Current measurement resolution | mA | 3 | 3 | 3 | 1 | 1 | |