Search

Categories

  New 
  Used 

Manufacturers

CMM-10

Frequency measurement; 10 MHz
Measuring DC / AC; 400 mV - 600 V
The measurement of dc / ac; 400,0 uA - 10,00 A

More details

Automatic or manual ranging,
HOLD function enables the measurement reading in poor light or in hard to reach places,
REL function allows you to make measurements relative
sound signaling Continuity (Beeper)
automatically disable unused device.
3 7/8 digits display (max. 5000).
Frequency Measurement

Range Resolution Accuracy
5,000 Hz 0,001 Hz ± (1.5% W. M. + 5 digits)
50.00 Hz 0.01 Hz
500.0 Hz 0.1 Hz ± (1.2% W. M. + 3 digits)
5,000 kHz, 0.001 kHz
50.00 kHz, 0.01 kHz
500.0 kHz, 0.1 kHz
5,000 MHz 0,001 MHz ± (1.5% W. M. + 4 digits)
10.00 MHz 0.01 MHz
Sensitivity: the minimum value of the effective voltage 8 V
Cycle Measurements (filling)

Range Resolution Accuracy
0.1 ... 99.9% ± 0.1% (1.2% W. M. + 2 digits)
Sensitivity: the minimum value of the effective voltage 8 V
Pulse width: 100us - 100 ms
the frequency range of 5 Hz ... 150 kHz.
Temperature measurement
 

Range Resolution Accuracy *
-20 ° C ... + 760 ° C ± 1 ° C (3% W.M. + 5 ° C 9 ° F)
-4 ° F ... + 1400 ° C 1 ° F
*) Without error temperature sensor type K

DC Voltage Measurement

Range Resolution Accuracy
400.0 mV ± 0.1 mV (0.5% W. M. + 2 digits)
4.000 V, 0.001 V ± (1.2% W. M. + 2 digits)
40.00 V, 0.01 V ± (1.2% W. M. + 2 digits)
400.0 V 0.1 V
600 V 1 V ± (1.5% W. M. + 2 digits)
Input impedance: 7.8 Mohm
AC Voltage Measurement

Range Resolution Accuracy
400.0 mV ± 0.1 mV (1.5% W. M. + 70 digit)
4.000 V, 0.001 V ± (1.2% W. M. + 3 digits)
40.00 V, 0.01 V ± (1.5% W. M. + 3 digits)
400.0 V 0.1 V
600 V 1 V ± (2.0% W. M. + 4 digits)
Input impedance: 7.8 Mohm,
the frequency range 50 ... 400 Hz.
Measuring DC

Range Resolution Accuracy
400.0 uA 0.1 uA ± (1.0% W. M. + 3 digits)
4 uA 000 uA 1 ± (1.5% W. M. + 3 digits)
40.00 mA 0.01 mA
400.0 mA 0.1 mA
4,000 A 0,001 A ± (2.5% W. M. + 5 digits)
10.00 A 0.01 A
AC current measurement

Range Resolution Accuracy
400.0 uA 0.1 uA ± (1.5% W. M. + 5 digits)
4 uA 000 uA 1 ± (1.8% W. M. + 5 digits)
40.00 mA 0.01 mA
400.0 mA 0.1 mA
4,000 A 0,001 A ± (3.0% W. M. + 7 digits)
10.00 A 0.01 A
the frequency range 50 ... 400 Hz.
Resistance Measurement
 

Range Resolution Accuracy
400.0 Ω 0.1 Ω ± (1.2% W. M. + 4 digits)
Kohm 4,000 0,001 kW ± (1.0% W. M. + 2 digits)
40.00 kohm 0.01 kW ± (1.2% W. M. + 2 digits)
400.0 kOhm 0.1 kOhm
4,000 0,001 Mohm Mohm
40.00 Mohm Mohm ± 0.01 (2.0% W. M. + 3 digits)
Capacitance measurement:

Range Resolution Accuracy
40.00 nF 0.01 nF ± (5.0% W. M. + 7 digits)
400.0 nF 0.1 nF ± (3.0% W. M. + 5 digits)
4,000 0,001 uF uF
40.00 uF 0.01 uF
100.0 uF 0.1 uF ± (5.0% W. M. + 5 digits)
The abbreviation "W. M." means "the measured value."

Electrical safety:

type of insulation: double, according to EN 61010 - 1 and IEC 61557
Measurement Category II 600 V according to EN 61010 - 1: 2004
ingress protection according to EN 60529: IP40
Other technical data:

rozasilanie meter: 9 V battery type 6LR61
diode test: I = 0.3 mA U0 = 1.5 V DC
continuity test: I <0.3 mA, a beep for R <50 Ω
over-range indication: the symbol 0L
frequency measurements: 2 readings per second
Input impedance: 7.8 Mohm (V AC / DC)
Display: LCD readout functions with indices 5000
Dimensions: 138 x 68 x 37 mm
Meter weight: 210 g
Fuses: range mA, uA 0.5 A / 250 V high-speed range A: 10 A / 250 V fast
Idle time for auto-off: 30 minutes
compliance with standards: EN 61010 - 1: 2004 BS EN 61010 - 2-032
quality standard ISO 9001
Nominal conditions:

Operating temperature: 0 ... + 50 ° C and humidity <70%
Storage temperature: -20 ... + 60 ° C and humidity <80%

Specials

» All specials

Contact us

Our hotline is available from Monday to Friday

+48 58 742 11 27

info@LabAparaty.pl