Schaffner NSG5004A
  USED  

Battery Simulator

More details

shop/bilder/NSG5004A.JPGThe NSG5004A has been generally designed for use within the
Automotive industry and, as such, is normally driven by a
NSG5000, NSG5500, NSG5200 and NSG5600 series instrument.

The NSG5004A is capable of ?30V, 25A.
It is programmed using a differential input voltage and has a gain
of -3.75 (i.e. it is an inverting amplifier).
A 1 - 10V differential input allows the NSG5004A output current capability
to be programmable from 10% of maximum current to full current,
regardless of the configuration.
This is useful for protecting the DUT from power overload, in DUT fail situations.

The instrument operates from 90 VAC to 264 VAC and is factory configured
to the correct mains input voltage.
The NSG5004A is housed in a 7U 84HP chassis.